Technical
and Product Details
|
||||||||||||||||||||||
|
SGN
Series
|
![]() |
|||||||||||||||||||||
|
Solar Power Module Specifications Lighting
system consists of Solar Power Module and Floodlight luminaire. See
Standard Luminaires for Floodlight
information
|
||||||||||||||||||||||
|
Mounting Bracket Assembley 1. Solar panels can be revolved 360 degrees and rotated 90 degrees to insure a south facing direction. 2. Solar panels supported and protected with aluminium npanel pans 3. Vented aluminium battery box holds batteries and controller 4. Sturdy schedule 40 aluminium and stainless steel hardware 5. Mounts on any pole 4 inch outside diameter or greater |
||||||||||||||||||||||
|
Power Components |
||||||||||||||||||||||
Single Panel 53w-3.2A 64w-3.65A 77w-4.55A 83w-4.85A
53w-20x44 64w-20x44 77w-26x44 83w-26x44
1=80AH or 1=98AH
53w-115lb-6.3sf 64w-120lb-6.3sf 77w-130lb-7.6sf 83w-130lb-7.6sf |
Double Panel 106w-6.4A 128w-7.3A eee ee
106w-40x44 128w-40x44 e e
2=160AH or 2=196AH
106w-170lb-10.5sf 128w-180lb-10.5sf
|
|||||||||||||||||||||
Panel Wattage-Output Amps Solarex MSX Series
Module Dimensions(inches )
Batteries - Maintenance Free Cell Number-Total Amp. Hour Capacity
Weight and Effective Projected Area (EPA) Rating(w), Weight(lb)-EPA(sqft-sf)@45 Degrees (includes Power Unit Only) |
||||||||||||||||||||||
Controllers |
||||||||||||||||||||||
SCU-1 16 Amps 20 Amps 10.75VDC 12.35 VDC 15 VDC 14.4 VDC VOC<4 VDC VOC>8 VDC |
Morningstar 20 Amps 20 Amps 11.7 VDC 12.8 VDC N/A 14.1 VDC VOC<6VDC VOC>10 VDC |
|||||||||||||||||||||
Input Maximum Current Load Current Maximum Low Voltage Disconnect ( LVD) Low Voltage Reconnect (RVR) High Voltage Disconnetc (HVD) Charge Stop Voltage Dusk Set Point Dawn Set Point |
||||||||||||||||||||||
| Go back to Product Details | ![]() |
|||||||||||||||||||||